How to use it
- Pick the existing assembly or enter its R-value.
- Choose an insulation material and thickness (edit the R per inch to match the label).
- Enter the area, your heating degree days and what your heat costs.
- Read the new R-value, the inches needed for your target, the savings and the payback.
What this insulation calculator does
This insulation calculator answers the three questions you have before you buy a single bag or batt. What R-value will the attic or wall have after you add insulation? How much insulation do you need to reach a target such as R-49 or R-60? And what will it save you each year, so you can judge the payback?
Start from a preset or type in the R-value of what you have now. Pick a material from the list; each one has a typical R per inch that you can overwrite with the number printed on the package. A thickness table shows the result for several depths side by side, and a simple materials line multiplies area by your installed cost per square foot.
US units (R-value, square feet, inches, °F heating degree days) are the default, and one click switches to metric (RSI, U-value in W/m²K, cm). Export the results to PDF or Excel for free, with no sign-up. Everything is calculated in your browser; nothing is uploaded.
R-value formula and savings formula
R-values of layers add up. Adding insulation to an existing assembly gives:
R(new) = R(existing) + thickness in inches × R per inch
Heat flow is the inverse, the U-factor: U = 1 / R (Btu per hour, per square foot, per °F). The calculator works the same way in metric: U' = 1 / (1/U + d/λ), where d is thickness in meters and λ is the conductivity in W/mK. One US R equals 0.1761 m²K/W.
To find how much insulation you need for a target:
inches = (R(target) − R(existing)) / R per inch
Yearly savings come from heating degree days (HDD, base 65 °F):
heat saved (Btu/yr) = (U(old) − U(new)) × area × HDD × 24
Divide by 3,412 to get kWh, or by 100,000 for therms. Then multiply by what a unit of delivered heat costs you: fuel price divided by furnace or boiler efficiency.
Worked example: topping up an attic
A 1,000 sq ft attic floor has old insulation that rates about R-11 in total. You add 12 inches of blown-in cellulose at R-3.5 per inch. The home sees about 5,000 °F·day HDD a year.
- New R-value: 11 + 12 × 3.5 = R-53.
- U-factors: 1/11 = 0.0909 before, 1/53 = 0.0189 after. The difference is 0.0720.
- Heat saved: 0.0720 × 1,000 × 5,000 × 24 = about 8.64 million Btu a year, which is about 2,534 kWh or 86 therms of heat.
- If delivered heat costs you $0.05 per kWh (enter your own fuel price and efficiency), that is about $127 a year. Enter your installed cost per sq ft and the calculator shows the simple payback.
To reach R-60 from R-11 you need R-49 more: 49 / 3.5 = 14.0 in of cellulose, or 49 / 2.5 = 19.6 in of blown fiberglass. Settled depth is what counts, so check the bag chart for the installed depth that delivers the rated R-value.
R-value per inch and recommended attic levels
Typical R per inch used as defaults (always prefer the R-value on the product label):
| Material | R per inch |
|---|---|
| Blown-in fiberglass | 2.5 |
| Fiberglass batts | 3.4 |
| Blown-in cellulose | 3.5 |
| Open-cell spray foam | 3.7 |
| EPS rigid foam | 4.0 |
| Mineral wool batts | 4.2 |
| XPS rigid foam | 5.0 |
| Polyiso rigid foam | 6.0 |
| Closed-cell spray foam | 6.5 |
ENERGY STAR publishes attic recommendations based on the 2021 IECC (Table R402.1.3):
| Climate zone | Uninsulated attic | Existing 3–4 in |
|---|---|---|
| 1 | R-30 | R-25 |
| 2 and 3 | R-49 | R-38 |
| 4 to 8 | R-60 | R-49 |
Local code can differ, so check with your building department for new work.
Tips and common mistakes
- Air seal first. Gaps around top plates, can lights and attic hatches leak warm air that no R-value stops. The formula assumes an airtight layer.
- Do not compress batts. A batt squeezed into a shallower cavity loses R-value.
- Framing is a thermal bridge. Studs and joists conduct more heat than the insulation between them, so a wall's whole-assembly R is lower than the cavity label.
- Savings are not your whole bill. Only the insulated area changes; windows, air leakage and hot water stay the same. For whole-room heat loss see the radiator size calculator.
- Diminishing returns are real. Each added inch saves less than the one before, which the thickness table makes easy to see.
The result is an estimate for planning, not an energy audit or financial advice.
Frequently asked questions
How much insulation do I need in my attic?
ENERGY STAR recommends R-49 to R-60 for an uninsulated attic in most of the US (R-30 in zone 1). Enter your existing R-value and the target, and the calculator gives the inches for the material you pick, for example 14 inches of cellulose to go from R-11 to R-60.
What is the difference between R-value and U-factor?
R-value measures resistance to heat flow, so higher is better. U-factor is its inverse (U = 1/R) and measures how much heat gets through, so lower is better. Window ratings usually use U-factor; insulation uses R-value.
Can I add new insulation on top of old insulation?
Usually yes, if the old insulation is dry and not moldy or pest-damaged. R-values add, so the calculator simply adds the new layer to the existing R-value. Use unfaced batts or loose fill on top so you do not create a vapor barrier in the middle.
Where do I find heating degree days for my area?
Weather services and utilities publish HDD for base 65 °F. Colder climates have higher numbers. Use a yearly total; the calculator multiplies it by 24 to get degree-hours.
How accurate is the savings estimate?
It is a steady-state estimate that ignores air leakage, sun and thermal bridges, so treat it as a planning number. It is most useful for comparing thicknesses and materials, not for predicting your exact bill.
Is the export free?
Yes. You can download the results and the thickness table as PDF or Excel with no sign-up and no watermark.
Sources
Last updated: November 13, 2026